1. Home
  2.  » 
  3. Products
  4.  » ecoPAD Filter System

e-breathe ecoPAD Filtersystem

Because resources are continuously becoming scarcer, more and more focus is placed on the sustainability of products. With the new ecoPAD filter system e-breathe follows this environmentally friendly and goes one step further.

SUSTAINABLE & EFFICIENT: THE ECOPAD SYSTEM ON THE NEW E-FLOW BY E-BREATHE
The e-breathe division developed a reusable filter which was designed with a screw on filter housing to reuse the filter housing and quickly and easily replace the filter fleece. The integrated fleece is exactly the same fleece, which is used in standardized encapsulated filters. The tight fit of the fleece is achieved through a special rubber coating that was developed specifically for the eco-PAD.

The top and the bottom of the filter housing can be connected at once and encloses the particulate fleece firmly. This means that the user has the highest protection against particles and aerosols and the lowest breathing resistance simultaneously.

The new e-Flow from e-breathe integrates the lower part of the filter housing directly onto the „PAD-Box“. The filter fleece is inserted into the integrated housing before using the e-Flow. The fleece will then be firmly closed with the upper part of the filter housing. Depending on the environmental air and the requirements, a particle filter or combination filter can be used.

Construction e-breathe filter system:
Example: Combination filter

1. Filter holder (DIN-RG connection)
2. ecoPAD GF (gas filter medium)
3. gas filter adapter
4. ecoPAD P3 ( particle filter medium)
5. Filter cover

modular exchange of the combination filter:
A modular exchange is possible when used with a combination filter if one filter is saturated. If necessary, only the particle or gas filter can be replaced separately. As a result, only the saturated filter can be replaced and the other filter can be used until saturated.

Space saving:
During the development of the ecoPADs, it was explicitly designed to be particularly flat and light. This means that only about one third of the space that would be required for storing conventional filters is required for storage.

Cost-effective:
The ecoPAD respiratory protection filters do not only score with space and cost savings in logistics and storage, but also protect the environment and material budget due to the reusable, modular design of the filter housing and the longer utilization of the particle or gas filter until saturation.

e-breathe e-Flow with PAD system:
The new e-breathe e-Flow with PAD-Box has an integrated ecoPAD holder directly into the housing. The corresponding ecoPAD is inserted directly into the blower and then closed tightly with the corresponding filter adapters.

The unique concept saves the DIN round thread connection, making the entire unit flatter and lighter. Depending on the ambient air and requirements, a particle, gas or combination filter can be used.

Particle filter (encapsulate)

e-breathe Partikelfilter P3 R SL (encapsulate)

Protects against solid and liquid particles, radioactive and toxic particles, microorganisms, such as bacteria and viruses.

Art. No. 322002109

Suitable for:
– Full face mask and Halfmask with DIN round thread
– PAPR: e-breathe e-Flow & Smartblower

Approved: EN 143, EN 12941, EN 12942

Particle filter ecoPADs

e-breathe ecoPAD P3 R SL (filter medien)

protects against solid and liquid particles, radioactive and toxic particles, microorganisms, such as bacteria and viruses.

Art. No. 322002110 (VPE 4)

Suitable for:
– Full face mask and Halfmask with DIN round thread
– PAPR: e-breathe e-Flow & Smartblower

Approved: EN 143, EN 12941, EN 12942

Gas filter (encapsulate)

e-breathe Gas filter ABEK2

Organic, inorganic and acid gases and vapours, as well as ammonia.

Art. No. Cooming soon

Suitable for:
– Full face mask and Halfmask with DIN round thread
– PAPR: e-breathe e-Flow

Approved: EN 14387, EN 12941, EN 12942

e-breathe Gas filter A2B2

Organic and inorganic gases and vapours.

Art. No. Cooming soon

Suitable for:
– Full face mask and Halfmask with DIN round thread
– PAPR: e-breathe e-Flow

Approved: EN 14387, EN 12941, EN 12942

e-breathe Gas filter A2

Organic gases and vapours, such as solvents, with a boiling point above 65 °C.

Art. No. Cooming soon

Suitable for:
– Full face mask and Halfmask with DIN round thread
– PAPR: e-breathe e-Flow

Approved: EN 14387, EN 12941, EN 12942

Gas filter ecoPADs

e-breathe ecoPAD GF ABEK2

Replacement Gas Filter PAD:
Organic, inorganic and acid gases and vapours, as well as ammonia.

Art. No. Cooming soon

Suitable for:
– Full face mask and Halfmask with DIN round thread
– PAPR: e-breathe e-Flow

Approved: EN 14387, EN

e-breathe ecoPAD GF A2B2

Replacement Gas Filter PAD
Organic and inorganic gases and vapours.

Art. No. Cooming soon

Suitable for:
– Full face mask and Halfmask with DIN round thread
– PAPR: e-breathe e-Flow

Approved: EN 14387, EN 12941, EN 12942

e-breathe ecoPAD GF A2

Replacement Gas Filter PAD:
Organic gases and vapours, such as solvents, with a boiling point above 65 °C.

Art. No. Cooming soon

Suitable for:
– Full face mask and Halfmask with DIN round thread
– PAPR: e-breathe e-Flow

Approved: EN 14387, EN 12941, EN 12942

Combination Filter (encapsulate)

e-breathe Combination Filter A2B2E2K1-P3 R SL

Protection against organic, inorganic and acid gases and vapours, as well as ammonia and organic ammonia derivatives, solid and liquid particles harmful to health, such as radioactive and toxic substances and microorganisms.

Art. No. Cooming soon

Suitable for:
– Full face mask and Halfmask with DIN round thread
– PAPR: e-breathe e-Flow

Approved: EN143,  EN 14387, EN 12941, EN 12942

e-breathe Combination Filter A2B2-P3 R / PSL

Organic and inorganic gases and vapours, solid and liquid particles, radioactive and toxic particles and microorganisms.

Art. No. Cooming soon

Suitable for:
– Full face mask and Halfmask with DIN round thread
– PAPR: e-breathe e-Flow

Approved: EN143,  EN 14387, EN 12941, EN 12942

e-breathe Combination Filter A2-P3 R / PSL

Organic gases and vapours, such as solvents, with a boiling point above 65 °C, solid and liquid particles, radioactive and toxic particles, and microorganisms.

Art. No. Cooming soon

Suitable for:
– Full face mask and Halfmask with DIN round thread
– PAPR: e-breathe e-Flow

Approved: EN143,  EN 14387, EN 12941, EN 12942

Filter accessories

End cap for filter thread

The end cap for the filter thread protects the thread against dust and dirt.

Art. No. 146042507

e-breathe Filter Cover

Screwed onto e-Flow PAD box, filter holder or gas filter adapter to use / seal the ecoPAD P3.

Art. No. 322002131

e-breathe Gas Filter - Adapter

Screwed onto the e-Flow PAD box or filter holder to use / seal the ecoPAD GF.me.

Art. No. Coming soon

e-breathe Filter Holder

A DIN round thread connection is required to use the filters with half / full mask or e-Flow filter box.

Art. No. 322002128

e-breathe Spark Arrestor Inserts

The spark arrestor inserts are mounted directly into the filter cover and are used for work with flying sparks in order to prevent a filter fire (e.g. welding work).

Art. No. 322002138

e-breathe Cover Cap for Filter Cover

The cover is clicked into the filter cover and extends its service life. During storage, the cover protects against moisture and dust.

Art. No. Coming soon

e-breathe Decon Shower Cap

The shower cap is clicked onto the filter cover and prevents the penetration of water into the filter during rinsing / decontamination.

Art. No. Coming soon

e-breathe Pre filter

The pre-filter captures coarse particles and extends the life of the particle filter. The prefilter is mounted between the filter and the prefilter holder.

Art. No. 302052691 (20x)