Respiratory Protection Filter
It is essential to follow the manufacturer’s recommendations regarding filter type, number of filters, matching flow resistance, etc. when selecting filters for respiratory protection blowers. Only filters which are approved for the particular blower may be used. Always replace the entire set of filters whenever the filter is changed.
Particle Filter
Particle filters offer protection against particles and are divided into three classes according to their separation capacity: P1 / P2 / P3. A higher protection class includes a lower one. The filter medium in the particulate filter catches the particles and increases its resistance. As soon as the resistance of the filter becomes too high, the filter will need to be replaced.
Article no. |
Name |
Area of use |
Colour code |
Image |
---|---|---|---|---|
322002109 |
e-breathe Particle filter |
Non-encapsulated filter for use against solid and liquid toxic, radioactive and harmful particles as well as microorganisms such as bacteria and viruses.
Compatible with: - Half and full face masks with DIN round thread connection - Blower: e-breathe e-flow, Smartblower |
|
|
322002110 |
e-breathe ecoPAD |
Solid and liquid toxic, radioactive and harmful particles as well as microorganisms such as bacteria and viruses.
Compatible with: - Replacement filter media for e-breathe particle filters. - Blower: e-breathe e-flow PAD box |
|
|
100052676 |
PM Particle filter |
Solid and liquid toxic, radioactive and harmful particles, as well as microorganisms such as bacteria and viruses.
Compatible with: - Blower: Proflow SC, Proflow EX |
|
|
Gas filter
Gas filters provide protection against gases and vapours and are divided into three classes according to type and main area of application, depending on their performance. The absorption capacity of each filter class includes those of the lower classes of the same type. The activated carbon in the gas filter absorbs the various gases. As soon as the gas filter is saturated or exhausted, the gas breaks through. The user can detect this by smell and/or taste and the filter must be replaced.
Gas Filter (consisting of ecoPAD GF + Gas Filter Adapter + Filter Holder)
EN 148-1 / EN 143 / EN 14387 / EN 12941 / EN 12942
Article no. |
Name |
Area of use |
Colour code |
Image |
---|---|---|---|---|
322002147 |
e-breathe Gas filter |
Organic gases and vapours, such as solvents, with a boiling point above 65 °C.
Compatible with: - Full and half masks with DIN round thread connection - Blower: e-breathe e-flow |
|
|
322002146 |
e-breathe Gas filter A1B2EK1 |
Organic, inorganic and acid gases and vapours, as well as ammonia.
Compatible with: - Full and half masks with DIN round thread connection - Blower: e-breathe e-flow |
|
|
Replacement pads for ecoPAD filters:
EN 148-1 / EN 143 / EN 14387 / EN 12941 / EN 12942
Article no. |
Name |
Area of use |
Colour code |
Image |
---|---|---|---|---|
322002144 |
e-breathe ecoPAD |
Organic gases and vapours, such as solvents, with a boiling point above 65 °C.
- Replacement gas filter PAD Compatible with: - Blower: e-breathe e-flow PAD box |
|
|
322002143 |
e-breathe ecoPAD |
Organic, inorganic and acid gases and vapours, as well as ammonia.
Replacement gas filter PAD Compatible with: - Blower: e-breathe e-flow PAD box |
|
|
Combination filter
Combination filters are a combination of a gas filter and a particle filter. They therefore offer protection against gases, vapours and particles. They must be replaced as soon as one of the two components is saturated.
Article no. |
Name |
Area of use |
Colour code |
Image |
---|---|---|---|---|
322012147 |
e-breathe |
Organic gases and vapours, such as solvents, with a boiling point above 65 °C, solid and liquid particles, radioactive and toxic particles, as well as microorganisms.
Compatible with: - Blower: e-breathe e-Flow |
|
|
322012146 |
e-breathe |
Protects against organic, inorganic and acidic gases and vapours, as well as ammonia and organic ammonia derivatives, solid and liquid particles that are harmful to health, such as radioactive and toxic substances and microorganisms.
Compatible with: - Blower: e-breathe e-Flow |
|
|
Encapsulated filters with DIN round thread connection
according to EN 143 / EN 14387 / EN 12941 / EN 12942
Article no. |
Name |
Area of use |
Colour code |
Image |
---|---|---|---|---|
100043173 |
PM Combination filter |
Organic gases and vapours, such as solvents, with a boiling point above 65 °C, solid and liquid particles, radioactive and toxic particles, as well as microorganisms. |
|
|
100043174 |
PM Combination filter |
Organic and inorganic gases and vapours, solid and liquid particles, radioactive and toxic particles and microorganisms. |
|
|
100043191 |
PM Combination filter |
Organic, inorganic and acidic gases and vapours as well as ammonia and organic ammonia derivatives, solid and liquid particles that are harmful to health, such as radioactive and toxic substances and microorganisms. |
|
|
Filter Accessories only for e-breathe Filter
Article no. |
Name |
Area of application |
Image |
---|---|---|---|
322052606 |
e-breathe |
The pre-filter holder is clicked onto the filter cover and is required to use the pre-filter and the spark arrester. The holes on the side of the pre-filter holder prevent direct suction. |
|
302052691 |
e-breathe Pre-filter |
The prefilter keeps out coarse particles and extends the life of the particulate filter. The prefilter is fitted between the prefilter holder and the filter cover. |
|
322002131 |
e-breathe |
Is screwed onto the e-Flow PAD box, filter holder or gas filter adapter to use / seal the ecoPAD P3. |
|
322002246 |
e-breathe |
Is screwed onto the e-Flow PAD box or filter holder to use / seal the ecoPAD GF. |
|
322002128 |
e-breathe |
Mount with DIN round thread connection is required to use the filters with half/full face mask or e-Flow filter box. |
|
322002225 |
e-breathe Cover Cap for Filter Lid |
The sealing cover is clicked onto the filter cover and extends its service life. During storage, the cover protects against moisture and dust. It protects the PAPR during cleaning. |
|
322002224 |
e-breathe Decon |
The shower cap is clicked onto the filter cover and prevents water from entering the filter during showering / decontamination. |
|
322002138 |
e-breathe |
The spark protection inserts are fitted directly into the filter cover or pre-filter holder and are used when working with flying sparks to prevent a filter fire (e.g. welding work). |
|
146042507 |
Sealing cap for filter thread |
The cap is placed on the round thread of the filter and extends its service life. The cover protects against moisture and dust during storage. |
|
Filter accessories only for PM Filter
Article no. |
Name |
Area of use |
Image |
---|---|---|---|
302052691 |
e-breathe Prefilter |
The pre-filter keeps out coarse particles and extends the service life of the particle filter. The pre-filter is fitted between the pre-filter holder and filter cover. |
|
302052692 |
PM Prefilter set |
The pre-filter retains coarse particles and thus extends the service life of the particle filter. The pre-filter is fitted between the filter and pre-filter holder. |
|
500052693 |
PM Cover Cap for Filter |
The sealing cover extends the service life of the filter. The cover protects against moisture and dust during storage. |
|
500580013 |
PM Decon Shower |
Cover cap for PM filter. Prevents water from entering the filter when showering / decontaminating. |
|
146042507 |
Sealing cap for |
The cap is placed on the round thread of the filter and extends its service life. The cover protects against moisture and dust during storage. |
|