Respiratory Protection Filter
It is essential to follow the manufacturer’s recommendations regarding filter type, number of filters, matching flow resistance, etc. when selecting filters for respiratory protection blowers. Only filters which are approved for the particular blower may be used. Always replace the entire set of filters whenever the filter is changed.

Particle Filter

e-breathe Particle filter P3 R SL (encapsulate)
Art. No. 322-002-109
Protects against solid and liquid particles, radioactive and toxic particles, microorganisms, such as bacteria and viruses.
Suitable for:
– Full face mask and Halfmask with DIN round thread
– PAPR: e-breathe e-Flow & Smartblower
Approved: EN 143, EN 12941, EN 12942

e-breathe ecoPAD P3 R SL (filter medien)
Art. No. 322-002-110 (VPE 4)
Protects against solid and liquid particles, radioactive and toxic particles, microorganisms, such as bacteria and viruses.
Suitable for:
– Full face mask and Halfmask with DIN round thread
– PAPR: e-breathe e-Flow & Smartblower
Approved: EN 143, EN 12941, EN 12942

PM Particle filter P3 R SL (encapsulated)
Art. No. 100-052-676
Protects against solid and liquid particles, radioactive and toxic particles, microorganisms, such as bacteria and viruses
Suitable for:
– Full face mask and Halfmask with DIN round thread
– PAPR: Proflow
Approved: EN 143, EN 12941, EN 12942
Gas filter

e-breathe Gas filter ABEK2
Art. No. Coming soon
Organic, inorganic and acid gases and vapours, as well as ammonia.
Suitable for:
– Full face mask and Halfmask with DIN round thread
– PAPR: e-breathe e-Flow
Approved: EN 14387, EN 12941, EN 12942

e-breathe Gas filter A2B2
Art. No. Coming soon
Organic and inorganic gases and vapours.
Suitable for:
– Full face mask and Halfmask with DIN round thread
– PAPR: e-breathe e-Flow
Approved: EN 14387, EN 12941, EN 12942

e-breathe Gas filter A2
Art. No. Coming soon
Organic gases and vapours, such as solvents, with a boiling point above 65 °C.
Suitable for:
– Full face mask and Halfmask with DIN round thread
– PAPR: e-breathe e-Flow
Approved: EN 14387, EN 12941, EN 12942

e-breathe ecoPAD GF ABEK2
Art. No. Coming soon
Replacement Gas Filter PAD:
Organic, inorganic and acid gases and vapours, as well as ammonia.
Suitable for:
– Full face mask and Halfmask with DIN round thread
– PAPR: e-breathe e-Flow
Approved: EN 14387, EN

e-breathe ecoPAD GF A2B2
Art. No. Coming soon
Replacement Gas Filter PAD
Organic and inorganic gases and vapours.
Suitable for:
– Full face mask and Halfmask with DIN round thread
– PAPR: e-breathe e-Flow
Approved: EN 14387, EN 12941, EN 12942

e-breathe ecoPAD GF A2
Art. No. Coming soon
Replacement Gas Filter PAD:
Organic gases and vapours, such as solvents, with a boiling point above 65 °C.
Suitable for:
– Full face mask and Halfmask with DIN round thread
– PAPR: e-breathe e-Flow
Approved: EN 14387, EN 12941, EN 12942
Combination filter

e-breathe Combination filter A2B2E2K2-P3 R SL
Art. No. Coming soon
Protection against organic, inorganic and acid gases and vapours, as well as ammonia and organic ammonia derivatives, solid and liquid particles harmful to health, such as radioactive and toxic substances and microorganisms.
Suitable for:
– Full face mask and Halfmask with DIN round thread
– PAPR: e-breathe e-Flow
Approved: EN143, EN 14387, EN 12941, EN 12942

e-breathe Combination filter A2B2-P3 R SL
Art. No. Coming soon
Organic and inorganic gases and vapours, solid and liquid particles, radioactive and toxic particles and microorganisms.
Suitable for:
– Full face mask and Halfmask with DIN round thread
– PAPR: e-breathe e-Flow
Approved: EN143, EN 14387, EN 12941, EN 12942

e-breathe Combination filter A2-P3 R SL
Art. No. Coming soon
Organic gases and vapours, such as solvents, with a boiling point above 65 °C, solid and liquid particles, radioactive and toxic particles, and microorganisms.
Suitable for:
– Full face mask and Halfmask with DIN round thread
– PAPR: e-breathe e-Flow
Approved: EN143, EN 14387, EN 12941, EN 12942

PM Combination filter A2B2E2K2-P3 R SL
Art. No. 100-043-191
Protection against organic, inorganic and acid gases and vapours, as well as ammonia and organic ammonia derivatives, solid and liquid particles harmful to health, such as radioactive and toxic substances and microorganisms.
Suitable for:
– Full face mask & Halfmask with DIN round thread
– PAPR: Proflow
Approved: EN 14387, EN 12941, EN 12942

PM Combination filter A2B2-P3 R SL
Art. No. 100-043-174
Organic and inorganic gases and vapours, solid and liquid particles, radioactive and toxic particles and microorganisms.
Suitable for:
– Full face mask & Halfmask with DIN round thread
– PAPR: Proflow
Approved: EN 14387, EN 12941, EN 12942

PM Combination filter A2-P3 R SL
Art. No. 100-043-173
Organic gases and vapours, such as solvents, with a boiling point above 65 °C, solid and liquid particles, radioactive and toxic particles, and microorganisms.
Suitable for:
– Full face mask & Halfmask with DIN round thread
– PAPR: Proflow
Approved: EN 14387, EN 12941, EN 12942
Filter accessories only for e-breathe Filter

e-breathe Filtersystem
Components: e-breathe Filter Housing

e-breathe Filter Cover
Art. No. 322-002-131
Screwed onto e-Flow PAD box, filter holder or gas filter adapter to use / seal the ecoPAD P3.

e-breathe Gas Filter Adapter
Art. No. Coming soon
Screwed onto the e-Flow PAD box or filter holder to use / seal the ecoPAD GF.

e-breathe Filter Holder
Art. No. 322-002-128
A DIN round thread connection is required to use the filters with half / full mask or e-Flow filter box.

e-breathe Spark Arrestor Inserts
Art. No. 322-002-138
The spark arrestor inserts are mounted directly into the filter cover and are used for work with flying sparks in order to prevent a filter fire (e.g. welding work).

e-breathe Cover Cap for Filter Cover
Art. No. Coming soon
The cover is clicked into the filter cover and extends its service life. During storage, the cover protects against moisture and dust.

e-breathe Decon Shower Cap
Art. No. Coming soon
The shower cap is clicked onto the filter cover and prevents the penetration of water into the filter during rinsing / decontamination.

e-breathe Pre filter
Art. No. 302-052-691 (20x)
The pre-filter captures coarse particles and extends the life of the particle filter. The prefilter is mounted between the filter and the prefilter holder.
Filter accessories only for PM Filter

Cover Cap for PM Filter
Art. No. 500-052-693
The closing cap extends the service life of the filter. During storage, the cover protects against moisture and dust.

Pre filter Set
Art. No. 302-052-692
The pre-filter captures coarse particles and extends the life of the particle filter. The prefilter is mounted between the filter and the prefilter holder.

Decon Shower Cap
Art. No. 500-580-013
Decon Shower Cap for PM Filter. Prevents the penetration of water into the filter during rinsing / decontamination.

Prefilter Holder + Spark Arrestor
Art. No. 100-052-690
The prefilter holders and metal covers are attached to the filter and are used for work with flying sparks (e.g. welding work).
Filter accessories for PM & e-breathe Filter

Pre-filter
Art. No. 302-052-691 (20x)
The pre-filter has a diameter of 100mm and is notable for its very large volume and small filter resistance.

End cap for filter thread
Art. No. 146-042-507
The end cap for the filter thread protects the thread against dust and dirt.