When choosing a filter for the respirator blower it is important to follow the manufacturer’s recommendations regarding filter type, quantity of filters, flow resistane etc. Only filters which have been approved for use with the blower may be used. When changing the filter the entire filter set must be changed.

Particle Filter

e-breathe Partikelfilter P3 R SL (encapsulate)

Protects against solid and liquid particles, radioactive and toxic particles, microorganisms, such as bacteria and viruses.

Art. No. 322002109

Suitable for:
– Full face mask and Halfmask with DIN round thread
– PAPR: e-breathe e-Flow & Smartblower

Approved: EN 143, EN 12941, EN 12942

e-breathe ecoPAD P3 R SL (filter medien)

protects against solid and liquid particles, radioactive and toxic particles, microorganisms, such as bacteria and viruses.

Art. No. 322002110 (VPE 4)

Suitable for:
– Full face mask and Halfmask with DIN round thread
– PAPR: e-breathe e-Flow & Smartblower

Approved: EN 143, EN 12941, EN 12942

PM Partikelfilter P3 R SL (gekapselt)

 protects against solid and liquid particles, radioactive and toxic particles, microorganisms, such as bacteria and viruses

Art. No. 100052676

Suitable for:
– Full face mask and Halfmask with DIN round thread
– PAPR: Proflow

Approved: EN 143, EN 12941, EN 12942

Gas filter

e-breathe Gas filter ABEK2

Organic, inorganic and acid gases and vapours, as well as ammonia.

Art. No. Cooming soon

Suitable for:
– Full face mask and Halfmask with DIN round thread
– PAPR: e-breathe e-Flow

Approved: EN 14387, EN 12941, EN 12942

e-breathe Gas filter A2B2

Organic and inorganic gases and vapours.

Art. No. Cooming soon

Suitable for:
– Full face mask and Halfmask with DIN round thread
– PAPR: e-breathe e-Flow

Approved: EN 14387, EN 12941, EN 12942

e-breathe Gas filter A2

Organic gases and vapours, such as solvents, with a boiling point above 65 °C.

Art. No. Cooming soon

Suitable for:
– Full face mask and Halfmask with DIN round thread
– PAPR: e-breathe e-Flow

Approved: EN 14387, EN 12941, EN 12942

e-breathe ecoPAD GF ABEK2

Replacement Gas Filter PAD:
Organic, inorganic and acid gases and vapours, as well as ammonia.

Art. No. Cooming soon

Suitable for:
– Full face mask and Halfmask with DIN round thread
– PAPR: e-breathe e-Flow

Approved: EN 14387, EN

e-breathe ecoPAD GF A2B2

Replacement Gas Filter PAD
Organic and inorganic gases and vapours.

Art. No. Cooming soon

Suitable for:
– Full face mask and Halfmask with DIN round thread
– PAPR: e-breathe e-Flow

Approved: EN 14387, EN 12941, EN 12942

e-breathe ecoPAD GF A2

Replacement Gas Filter PAD:
Organic gases and vapours, such as solvents, with a boiling point above 65 °C.

Art. No. Cooming soon

Suitable for:
– Full face mask and Halfmask with DIN round thread
– PAPR: e-breathe e-Flow

Approved: EN 14387, EN 12941, EN 12942

Combination Filter

e-breathe Combination Filter A2B2E2K1-P3 R SL

Protection against organic, inorganic and acid gases and vapours, as well as ammonia and organic ammonia derivatives, solid and liquid particles harmful to health, such as radioactive and toxic substances and microorganisms.

Art. No. Cooming soon

Suitable for:
– Full face mask and Halfmask with DIN round thread
– PAPR: e-breathe e-Flow

Approved: EN143,  EN 14387, EN 12941, EN 12942

e-breathe Combination Filter A2B2-P3 R / PSL

Organic and inorganic gases and vapours, solid and liquid particles, radioactive and toxic particles and microorganisms.

Art. No. Cooming soon

Suitable for:
– Full face mask and Halfmask with DIN round thread
– PAPR: e-breathe e-Flow

Approved: EN143,  EN 14387, EN 12941, EN 12942

e-breathe Combination Filter A2-P3 R / PSL

Organic gases and vapours, such as solvents, with a boiling point above 65 °C, solid and liquid particles, radioactive and toxic particles, and microorganisms.

Art. No. Cooming soon

Suitable for:
– Full face mask and Halfmask with DIN round thread
– PAPR: e-breathe e-Flow

Approved: EN143,  EN 14387, EN 12941, EN 12942

PM Combination Filter A1B2E2K2-P3 R / PSL

Protection against organic, inorganic and acid gases and vapours, as well as ammonia and organic ammonia derivatives, solid and liquid particles harmful to health, such as radioactive and toxic substances and microorganisms.

Art. N0. 100043191

Suitable for:
– Full face mask & Halfmask with DIN round thread
– PAPR: Proflow

Approved: EN 14387, EN 12941, EN 12942

PM Combination Filter A2B2-P3 R / PSL

Organic and inorganic gases and vapours, solid and liquid particles, radioactive and toxic particles and microorganisms.

Art. No. 100043174

Suitable for:
– Full face mask & Halfmask with DIN round thread
– PAPR: Proflow

Approved: EN 14387, EN 12941, EN 12942

PM Combination Filter A2-P3 R / PSL

Organic gases and vapours, such as solvents, with a boiling point above 65 °C, solid and liquid particles, radioactive and toxic particles, and microorganisms.

Art. No. 100043173

Suitable for:
– Full face mask & Halfmask with DIN round thread
– PAPR: Proflow

Approved: EN 14387, EN 12941, EN 12942

Filter accessories only for e-breathe Filter

e-breathe Filtersystem

Components: e-breathe Filter Housing

e-breathe Filter Cover

Screwed onto e-Flow PAD box, filter holder or gas filter adapter to use / seal the ecoPAD P3.

Art. No. 322002131

e-breathe Gas Filter - Adapter

Screwed onto the e-Flow PAD box or filter holder to use / seal the ecoPAD GF.me.

Art. No. Coming soon

e-breathe Filter Holder

A DIN round thread connection is required to use the filters with half / full mask or e-Flow filter box.

Art. No. 322002128

e-breathe Spark Arrestor Inserts

The spark arrestor inserts are mounted directly into the filter cover and are used for work with flying sparks in order to prevent a filter fire (e.g. welding work).

Art. No. 322002138

e-breathe Cover Cap for Filter Cover

The cover is clicked into the filter cover and extends its service life. During storage, the cover protects against moisture and dust.

Art. No. Coming soon

e-breathe Decon Shower Cap

The shower cap is clicked onto the filter cover and prevents the penetration of water into the filter during rinsing / decontamination.

Art. No. Coming soon

e-breathe Pre filter

The pre-filter captures coarse particles and extends the life of the particle filter. The prefilter is mounted between the filter and the prefilter holder.

Art. No. 302052691 (20x)

Filter accessoriesonly for PM Filter

Cover Cap for PM Filter

The closing cap extends the service life of the filter. During storage, the cover protects against moisture and dust.

Art. No. 500052693

Pre filter Set

The pre-filter captures coarse particles and extends the life of the particle filter. The prefilter is mounted between the filter and the prefilter holder.

Art. No. 302052692 

Decon Shower Cap

Decon Shower Cap for PM Filter. Prevents the penetration of water into the filter during rinsing / decontamination.

Art. No. 500580013

Prefilter Holder + Spark Arrestor

The prefilter holders and metal covers are attached to the filter and are used for work with flying sparks (e.g. welding work).

Art. No. 100052690

Filter accessories for PM & e-breathe Filter

Pre-filter

The pre-filter has a diameter of 100mm and is notable for its very large volume and small filter resistance.

Art. No. 302052691 (20x)

End cap for filter thread

The end cap for the filter thread protects the thread against dust and dirt.

Art. No. 146042507