e-breathe Chemical suits

Positive pressure suits

The e-breathe Chemical Suits are one-piece positive pressure respiratory protective suits that provide the highest level of protection against gases, vapors, solid and liquid chemicals, as well as radioactive contamination, solid and liquid aerosols and particulates. The suits are used in combination with an approved respirator blower or compressed air control valve. Each is available in two styles, with an internal blower or external air source. Equipped with a visor, booties and tapered sleeve, it offers high safety and flexibility. The suit has booties with boot covers and can be used with all suitable boots. The tapered sleeve allows for a liquid-tight connection between glove and suit, either by taping with chemical-resistant tape or by using the e-breathe glove adapter system. Maximum protection for the toughest conditions

For more information, please see our product catalog

e-breathe Chemical Grey

CHEMICAL GREY INSIDE

The respiratory protection blower is worn inside the suit (only the filters are outside) to avoid contamination of the blower. The associated respiratory protection blower supplies a constant (adjustable) fresh air flow of 160-200 liters per minute, via the breathing air hose into the air duct of the integrated hood. This reliably supplies the user with sufficient breathable air. The exhaled air is led out of the suit via four exhaust valves.

CERTIFIED ACCORDING TO EN STANDARDS:

• EN 12941: TH3 with blower filter unit
• EN 14605: Type 3 liquid-tight protective suits
• EN 14605: Type 4 spray-tight suits
• EN 13982: type 5 particle-tight suits
• EN 13034: type 6 conditional spray-tight protective suits
• EN 1073-2: Protection against solid radioactive particles
• EN 14126: type 3B / 4B protection against infectious agents
• EN 1149-1: antistatic properties
• EN 13688: protective clothing General requirements

e-breathe Chemical Grey Inside

e-breathe Chemical White

CHEMICAL WHITE INSIDE

The respiratory protection blower is worn inside the suit (only the filters are outside) to avoid contamination of the blower. The associated respiratory protection blower supplies a constant (adjustable) fresh air flow of 160-200 liters per minute, via the breathing air hose into the air duct of the integrated hood. This reliably supplies the user with sufficient breathable air. The exhaled air is led out of the suit via four exhaust valves.

CERTIFIED ACCORDING TO EN STANDARDS:

• EN 12941: TH3 with blower filter unit
• EN 14605: Type 3 liquid-tight protective suits
• EN 14605: Type 4 spray-tight suits
• EN 13982: type 5 particle-tight suits
• EN 13034: type 6 conditional spray-tight protective suits
• EN 1073-2: Protection against solid radioactive particles
• EN 14126: type 3B / 4B protection against infectious agents
• EN 1149-1: antistatic properties
• EN 13688: protective clothing General requirements

Atemschutzanzug Chemical White Inside

e-breathe Chemical Grey

CHEMICAL GREY OUTSIDE

The air supply is worn outside the suit. This option is required for rapid change (disaster response) of air sources and is therefore suitable for a variety of other air sources. The suit can be dressed and undressed easily and quickly. The system can be changed without removing the suit. The air source blower provides an adjustable fresh air flow of 160-200 liters per minute. The associated compressed air control valve provides a constant (adjustable) fresh air flow of 160-280 liters per minute, via the breathing air hose into the air duct of the integrated hood.

CERTIFIED ACCORDING TO EN STANDARDS:

• EN 12941: TH3 with blower filter unit
• EN 14605: Type 3 liquid-tight protective suits
• EN 14605: Type 4 spray-tight suits
• EN 13982: type 5 particle-tight suits
• EN 13034: type 6 conditional spray-tight protective suits
• EN 1073-2: Protection against solid radioactive particles
• EN 14126: type 3B / 4B protection against infectious agents
• EN 1149-1: antistatic properties
• EN 13688: protective clothing General requirements

Atemschutzanzug Chemical Grey Outside

e-breathe Chemical White

CHEMICAL WHITE OUTSIDE

The air supply is worn outside the suit. This option is needed for quick change (disaster response) of air sources and is therefore suitable for a variety of other air sources. The suit can be dressed and undressed easily & quickly. The system can be changed without taking off the suit. The blower serves as the air source and provides an adjustable fresh air flow of 160-200 liters per minute. The associated compressed air control valve delivers a constant (adjustable) fresh air flow of 160-280 liters per minute into the air duct of the integrated hood via the breathing air hose.

CERTIFIED ACCORDING TO EN STANDARDS:

• EN 12941: TH3 with blower filter unit
• EN 14605: Type 3 liquid-tight protective suits
• EN 14605: Type 4 spray-tight suits
• EN 13982: type 5 particle-tight suits
• EN 13034: type 6 conditional spray-tight protective suits
• EN 1073-2: Protection against solid radioactive particles
• EN 14126: type 3B / 4B protection against infectious agents
• EN 1149-1: antistatic properties
• EN 13688: protective clothing General requirements

Atemschutzanzug Chemical White Outside

ADVANTAGES OF A BLOWER-ASSISTED PROTECTIVE SUIT

Superior protection compared to protective suits:

Fan-assisted suits maintain a positive pressure inside the suit so that any air flow (through valves, zippers, or other design elements) is from the inside out, making the ingress of gases or vapors unlikely.

Superior comfort compared to coveralls and gas-tight suits:

Chemical protective suits are inherently uncomfortable to wear, but the internal respirator blower provides a constant, filtered airflow inside the suit. This gentle, continuous airflow helps regulate temperature, keeping the wearer cooler and increasing comfort.

Increased mobility and longer operating times:

The respirator worn on the back allows the user the greatest possible mobility. Compared to wearing a PAPR hood, the use of a PAPR full protective suit allows longer operating times with greater flexibility and consistent comfort.

e-breathe Chemical Grey Inside

Atemschutzanzug e-breathe Chemical Grey Inside

Article no. 322-009-12x Gr. S – XXL

e-breathe Chemical Grey Inside

Model: internal blower e-flow, tapered sleeve, booties with boot covers

Article no. 700-009-12x Gr. S – XXL

PM Chemical Grey Inside

Model: Internal blower Proflow, tapered sleeve, boot cover booties

e-breathe Chemical White Inside

Article no. 322-009-14x Gr. S – XXL

e-breathe Chemical White Inside

Model: internal blower e-Flow, tapered sleeve, boot cover booties.

e-breathe Chemical Grey Outside

Article no. 700-009-21x Gr. S – XXL

e-breathe Chemical Grey Outside

Model: External air source (e-Flow/ PM Proflow); Tapered sleeve, boot cover booties

e-breathe Chemical White Outside

Article no. 322-009-13x Gr. S – XXL

e-breathe Chemical White Outside

Model: External air source (e-Flow/ PM Proflow); Tapered sleeve, boot cover booties

Breathing Air Hoses

Atemschlauch feste Länge

Breathing Hoses fixed length

Art. No. 322-011-109
e-breathe Click-Connection

Atemschlauch Flexibel

Breathing Hoses flexible

Art. No. 322-001-109
e-breathe Click-Connection

Atemschlauch feste Länge

Breathing Hoses fixed length

Art. No. 302-001-111
e-breathe Inside-Connection

Atemschlauch Flexibel für Inside Überdruckschutzanzüge

Breathing Hoses flexible

Art. No. 322-001-111
e-breathe Inside-Connection

Atemschlauch Flexibel mit Mundstück

Breathing Hoses flexible

Art. No. 322-004-055
e-breathe ESA-Connection

Accessory & Spare Parts

e-breathe Ausatemventil

e-breathe Exhalation Valve

Art. No. 230-103-00

e-breathe Silikon Ventilblatt

e-breathe Flutter Valve

Art. No. 322-004-045

e-breathe Ausatemventil Produktschutz

e-breathe Exhalation Valve

Art. No. 230-103-009

Product Protection

e-breathe Produktschutz Vlies

e-breathe Product Protection Fleece

Art. No. 101-052-693

Protection Fleece (PU 50)

Ausatemventil Verschlusskappe

e-breathe Exhalation Valve Closure Caps

Art. No. 230-103-010

e-breathe GSA Adapter

e-breathe GSA Adapter

Art. No. 116-010-806

ESA Adapter Notbelüftung

e-breathe Adapter Emergency Ventilation

Art. No. 322-004-051

ESA Verschlussstopfen für Notbelüftung

e-breathe ESA Sealing Plug

Art. No. 322-004-058

Atemschutzanzug ESA Adapter

e-breathe ESA Adapter

Art. No. 322-004-053

ESA Not-Druckluftadapter

e-breathe ESA Emergency CA Adapter

Art. No. 322-004-058

Schutzstiefel

Protective Boots

Art. No. upon request

Schutzhandschuhe

Protective Gloves

Art. No. upon request

Unterziehanzug

Undergarment

Art. No. 700-012-60x Size M-XL

Schutzüberzug für Schläuche

Protective Cover

Art. No. 116-001-041

Limited-Use Protective cover for breathing air hoses.

Contact

e-breathe Safety

Willicher Damm 99

D-41066 Mönchengladbach

Phone: +49 (0) 2161 / 402900

info@e-breathe.de

Business Hours:

Mo. – Tu. 09.00 – 16.30 Uhr

Fr. 09.00 – 14.30 Uhr