e-breathe Lab Hood AV
Headpieces for PAPR/compressed air systems
The e-breathe Lab Hood AV offers the wearer high wearing comfort and effective protection. It provides eye and face protection against liquid splashes, dust, and low-energy airborne particles. The full hood is made of a particle-tight, low-noise, and lint-free material, featuring an integrated eye shield and shoulder coverage. The seams of the hood are precisely welded for maximum durability and hygiene.
When connected to an air supply—either a powered air respirator unit or a compressed air regulator valve—a constant positive pressure is maintained inside the hood.
This allows the hood to function self-supporting and without any internal head suspension.
The positive pressure system ensures the highest protection class is achieved while keeping the airflow comfortable, preventing it from blowing directly into the wearer’s face. The air stream circulates smoothly along the inside of the large polycarbonate visor, ensuring clear vision at all times.
The head harness can be universally adjusted to fit any head size. The bib can be worn either inside or outside a protective suit. When worn inside the suit, the exhaled air contributes to temperature balance and improved comfort within the suit.
Furthermore, there is no time limitation for wearing the hood, and no G26 medical examination is required, since the hood imposes no breathing resistance on the user.
The use of respiratory hoods is recommended in all areas where no additional mechanical head or eye protection is required. The Lab Hood is available in three different material versions, making it suitable for a wide range of applications.
Product Description Lab Hood
1) Headband
External headband allows individual adjustment to any head size.
2) Forehead Band
Fixes the hood and shapes the visor. The soft headband provides a high wearing comfort.
3) Hood Material
The hood is made of a low-noise, robust, crease- and lint-free material. The cover can be easily and quickly put on and is available as Limited-Use and Reusable Version.
4) Polycarbonate Visor
Comes flat, without unwanted creases and without reflection. Ergonomically shaped for a 320° distortion-free all-round view.
5) Exhalation Valve with Speech Membrane
The exhalation valve ensures direct discharge of the exhaled air and, thanks to the speech membrane, ensures good communication and a clear speech connection. The intelligently designed exhalation valve avoids heavy breathing resistance and allows a direct use of the hood without a G26 medical check-up.
7) Airflow
The airflow runs inside the hood on the inside of the PC visor. This prevents permanent fogging of the screen and prevents the user from feeling any unpleasant draught in the neck.
8) Quick-Lock Hose Connection
The breathing air hose is securely attached using the new Quick-Lock system on the adapter of the hood.
9) Quick-Lock Hose Connection
The breathing air hose is securely attached using the new Quick-Lock system on the adapter of the hood.
10) Shoulder cover
The shoulder cover can be worn inside or outside the protective suit. When worn inside, excess air is directed into the suit and aids heat regulation.
11) Neck Seal
The textile neck seal with elastic band ensures that the laboratory hood fits perfectly around the neck. It is therefore ideal for people who wear beards and glasses.
12) Product Short Facts
- Suitable for beard and glasses wearers
- No G26 preventive medical examination
- No wearing time limit
- Made in the EU
- Extremely low weight
Compatible Air Sources
Lab Hood - Versions
Lab Hood AV
(Limited-Use-Hood)
Limited-use hoods can be used multiple times and are ideal for applications requiring frequent replacement of the headpiece, where cleaning or disinfection would not be economical.
Lab Hood AV - Premium
(ReusableHood)
The Premium reusable version is made from a durable, water-repellent material suitable for multiple uses.
The hood can be cleaned and disinfected, providing a cost-effective and environmentally friendly solution.
Chemical Hood
(Chemical Protection)
The Chemical Hood is made from a low-noise, robust, crease-resistant, antistatic, and chemical-resistant material. It has been specifically designed for work environments with increased hazard potential, such as handling hazardous or toxic substances.
Technical specifications
| Country of Production: | Germany | Germany | Germany | Germany |
| Approvals: | CE certified according to EN 12941 | CE certified according to EN 12941 | CE certified according to EN 12941 | CE certified according to EN 14594 |
| Air source: | e-breathe e-Flow | Smartblower | PM Proflow 2 SC / EX | e-breathe e-Line |
| Protection Class: | TH3 | TH3 | TH3 | 3A |
| Airflow: | 160 – 180 – 200 l/min | 140 l/min | 120 l/min | 160 – 280 l/min |
| Hose Connection: | e-breathe Klick-System | e-breathe Klick-System | e-breathe Klick-System | e-breathe Klick-System |
| Operating temperature: | -10°C bis +40°C <70% RH | -10°C bis +40°C <70% RH | -10°C bis +40°C <70% RH | -0°C bis +40°C <70% RH |
| Weight: | 170g | 170g | 170g | 170g |
| Material Limited-Use: | Polysafe | Polysafe | Polysafe | Polysafe |
| Material Mehrweg: | Bluesafe | Bluesafe | – | Bluesafe |
For more information, please see our product catalog
Starter-Packs - Lab Hood Gen. 2.0 with Quick-Lock Connector
e-breathe Lab Hood AV Gen. 2.0
- Limited Use
Article no. 700011008
e-breathe Lab Hood AV Gen. 2.0
- Reusable
Art. No. 322025603
e-breathe Lab Hood AV Gen. 2.0
- Chemical
Art. No. 700010066
Ready-Packs - Lab Hood Gen. 2.0 with Quick-Lock Connector
Ready-Pack Smartblower One-Filter Chemical Hood
Article no. 322002120
Ready-Pack Smartblower One-Filter Lab Hood
Article no. 322002119
Ready-Pack Smartblower Two-Filter Chemical Hood
Article no. 322002127
Ready-Pack Smartblower Two-Filter Lab Hood
Article no. 322002126
Ready-Pack
e-Flow Lab Hood Premium
Article no. 322005301
Ready-Pack
e-Flow Lab Hood Limited-Use
Article no. 322005300
Starter-Packs - Lab Hood Gen. 1.0 with Click Connector
Ready-Packs - Lab Hood Gen. 1.0 with Click Connector
PM Lab Hood AV
Art. No. 700001008
PM Lab Hood AV
Art. No. 322015603
Ready-Pack Proflow
Art. No. 302001021
Ready-Pack Smartblower
Accessories & Spare Parts
Air Hose Gen. 2.0
Air Hose Gen. 1.0
Breathing Hose Quick-Lock
PU flexible
Art. No. 322001996
Breathing Hose Quick-Lock
PU fixed length
Art. No. 322002996
Breathing Hose Quick-Lock
EPDM
Art. No. 322001106
Breathing Hose Click
PU flexible
Article no. 322001109
Breathing Hose Click
PU fixed length
Article no. 322011109
Product Protection Fleece
Art. No. 101052692
O-Ring Helmet Holder
Art. No. 14200201
e-breathe Silicone Valve
Art. No. 322004045
Exhalation Valve Production
Art. No. 230103009
e-breathe Exhalation Valve
Art. No. 230103010
Click Adapter rings
Art. No. 402010002
Disinfectant
Art. No. 129001000
Spray Head
Art. No. 129001001
Protective Cover
Art. No. 116001041